Our Home Page

Cast Translucent Film - Specifications

2 MIL CAST FILM
TYPICAL VALUES
Results
PROPERTY TEST METHOD ENGLISH METRIC
Thickness Film Micrometer .02 ± 10% .050mm ± 10%
Thickness Adhesive Micrometer .001-.0012 .026mm - .032mm
Tensilee Strength Instron Tensile Tester - jaw separation 2 in. and a speed of 12 in. per min. 5 lb/in. minimum
73ºF
.9 kg/cm minimum
23ºC
Elongation

Instron Tensile Tester
(as above)

100% at 73ºF

100% minimum


For all properties given below, film was applied to an acrylic substrate at 73ºF (23ºC) 24 hours before testing.

Results
PROPERTY TEST METHOD ENGLISH METRIC
Temperature
Range
Good adhesion and minimal staining when exposed to any temperature within range specified. -20ºF to +175ºF -29ºC to 80º°C
Adhesion

180° pullback at 12” (30.5cm) per minute

4.0 lb/in.

0.7 kg/cm


CHEMICAL RESISTANCE

Unless otherwise specified, the film was applied to an acrylic substrate at 73ºF, 23ºC, 24 hours before testing. The samples are immersed in the noted chemical agent at 73ºF, 23ºC, and after testing are wiped clean.

Chemical Agent Exposure Time Results
Water 24 hours No effect
Mild soap and water 24 hours No effect
20% Isopropyl Alcohol/80% water 10 minutes No effect 10%
Hydrochloric Acid 10 minutes No effect
10% Ammonium Hydroxide 10 minutes No effect

Please contact us for more information.